SECTION 7
DESCRIPTION
TBM
700
PILOT’S OPERATING HANDBOOK
Page 7.14.1
Edition 1 -- November 30, 2010
Rev. 0
7.14 -- AVIONICS MASTER
(Figure 7.14.1)
The electrical supply of avionic equipment assembly is controlled by the
”AVIONICS MASTER” switch located on the upper panel.
When the “AVIONICS MASTER” switch is set to START, it allows to
electrically supply, from the “BATT BUS“ bar, a limited number of equipment.
One single COM, engine monitoring data and fuel indicating functions are
available. The L.H. station PFD only displays a reduced quantity of
information.