SUPPLEMENT 29
”EROS/INTERTECHNIQUE”
GASEOUS OXYGEN
SYSTEM
(30000 FT)
TBM
700
Page 9.29.7
Edition 1 -- November 30, 2010
Rev. 0
IN--FLIGHT AVAILABLE OXYGEN QUANTITY (Cont’d)
1 -- Determine the usable oxygen percent using the chart Figure
9.29.1.
Figure 9.29.1
2 -- Determine the oxygen duration in minutes by multiplying the
values read on table Figure 9.29.2 by the percent obtained with the
chart Figure 9.29.1.
Number of
passen-
gers
Duration :
Passengers,
plus 1 pilot
Duration :
Passengers,
plus 2 pilots
0
226
113
1
162
94
2
127
81
3
104
71
4
88
65
Figure 9.29.2