SUPPLEMENT 29
”EROS/INTERTECHNIQUE”
GASEOUS OXYGEN
SYSTEM
(30000 FT)
TBM
700
Page 9.29.11
Edition 1 -- November 30, 2010
Rev. 0
FLIGHT ABOVE 15000 FT WITH EMERGENCY DESCENT
Number of
occupants
OUTSIDE TEMPERATURE
Cockpit
Cabin
110
˚
F/
43
˚
C
90
˚
F/
32
˚
C
70
˚
F/
21
˚
C
50
˚
F/
10
˚
C
30
˚
F/
--1
˚
C
10
˚
F/
--12
˚
C
--10
˚
F/
--23
˚
C
1
0
451
435
418
399
381
365
346
1
1
567
545
525
501
479
457
435
1
2
685
657
632
605
578
550
522
1
3
802
770
740
707
674
642
608
1
4
920
882
847
809
772
734
696
2
0
937
898
864
824
783
745
709
2
1
1056
1009
971
925
881
837
792
2
2
1175
1123
1078
1027
977
928
875
2
3
1293
1234
1186
1115
1072
1014
961
2
4
1414
1349
1293
1228
1168
1106
1044
(Values in PSIG)
Conditions :
1. 4 minutes from 30000 to 15000 ft. All equipment used from 30000 ft.
2. Plus 30 minutes usage by each pilot and passenger at 15000 ft.
3. Plus 86 minutes usage by each pilot at 10000 ft.
NOTE :
After a long parking time in the sunshine, increase pressures indicated in the