TBM
700
SUPPLEMENT 29
”EROS/INTERTECHNIQUE”
GASEOUS OXYGEN
SYSTEM
(30000 FT)
Page 9.29.12
Edition 1 -- November 30, 2010
Rev. 0
WHEN REQUIRED TO REMAIN ABOVE 15000 FT DUE TO MINIMUM ”EN
ROUTE” ALTITUDE
Number of
occupants
OUTSIDE TEMPERATURE
Cockpit
Cabin
110
˚
F/
43
˚
C
90
˚
F/
32
˚
C
70
˚
F/
21
˚
C
50
˚
F/
10
˚
C
30
˚
F/
--1
˚
C
10
˚
F/
--12
˚
C
--10
˚
F/
--23
˚
C
1
0
464
447
430
410
393
376
357
1
1
672
646
621
593
567
539
513
1
2
880
843
811
773
738
702
665
1
3
1091
1044
1001
955
910
864
817
1
4
1300
1242
1191
1134
1077
1022
966
2
0
912
873
839
801
763
728
689
2
1
1122
1072
1029
980
934
885
840
2
2
1333
1271
1220
1163
1108
1045
991
2
3
1545
1472
1410
1342
1272
1203
1138
2
4
1755
1671
1600
1516
1436
1355
1262
(Values in PSIG)
Conditions :
1. Flight above 15000 ft. All equipment used.
2. 1 hour usage by each pilot and passenger.
3. Plus 1 hour usage by each pilot under 15000 ft.
NOTE :
After a long parking time in the sunshine, increase pressures indicated in the
table here above by 8 %.