TBM
700
SUPPLEMENT 37
”EROS/INTERTECHNIQUE”
GASEOUS OXYGEN
SYSTEM
(31000 FT)
Page 9.37.6
Edition 1 -- November 30, 2010
Rev. 0
SECTION 4
NORMAL PROCEDURES
The normal procedures hereafter supplement those of the standard airplane
described in Section 4 ”Normal procedures” of the basic Pilot’s Operating
Handbook, when the TBM 700 airplane is equipped with the option
””EROS/INTERTECHNIQUE” GASEOUS OXYGEN SYSTEM (31000 FT)”
and with MOD70--0276--00.
External
Rear R.H. karman
Oxygen cylinder open
Oxygen pressure
CHECK
Internal
Oxygen supply
Available for the planned flight
(see tables in Section 7
for a FAR 135 type operation)
”OXYGEN” switch
ON
”PASSENGERS OXYGEN” switch
OFF
Copilot and pilot masks
Press push--button
”PRESS TO TEST” :
the blinker shall turn red
momentarily, then turns transparent
”NORMAL/MASK” micro inverter
NORMAL
PREFLIGHT INSPECTION
IN--FLIGHT AVAILABLE
OXYGEN QUANTITY
Oxygen pressure
Read
Outside air temperature (OAT)
Read