TBM
700
SUPPLEMENT 37
”EROS/INTERTECHNIQUE”
GASEOUS OXYGEN
SYSTEM
(31000 FT)
Page 9.37.16
Edition 1 -- November 30, 2010
Rev. 0
If the pressure on the oxygen cylinder gage is lower, fill the oxygen cylinder.
Make sure the area around the oxygen cylinder charging valve is clean.
Remove the cap from the charging valve.
Make sure the oxygen supply hose is clean and connect it to the charging
valve.
Slowly pressurize the oxygen cylinder to the correct pressure.
Close the oxygen supply and let the cylinder temperature become stable.
Monitor the oxygen pressure on the gage and fill to the correct pressure if
necessary.
Release the pressure in the oxygen supply hose and disconnect from the
charging valve.
Install the cap on the charging valve.
Make sure all the tools and materials are removed and the work area is clean
and free from debris.
Close the oxygen service door.
PASSENGER MASKS REPACKING INSTRUCTIONS
WARNING
DO NOT USE OIL OR OTHER PETROLEUM BASED LUBRICANTS ON
PASSENGER OXYGEN MASK OR DEPLOYMENT CONTAINER. OIL
BASED LUBRICANTS ARE A FIRE HAZARD IN OXYGEN--RICH
ENVIRONMENTS
WARNING
REPACKING PROCEDURES SHALL BE PERFORMED BY
PERSONNEL FAMILIAR WITH THE INSTRUCTIONS AND WARNINGS
IN THIS DOCUMENT. IMPROPERLY PACKED MASKS CAN DAMAGE
THE MASKS OR RESULT IN FAILURE OF THE MASKS TO DEPLOY