3.4 -- AIR START
AIR START WITHOUT STARTER
(STARTER ASSIST NOT MANDATORY) (1/2)
CAUTION
THE STARTER CANNOT OPERATE IF THE ”GENERATOR”
SELECTOR IS ON ”ST--BY”
CAUTION
IGNITION IS NOT AVAILABLE IF THE ”ESS BUS TIE” SWITCH IS
KEPT ”EMER”
NOTE :
The “AVIONICS MASTER” switch may be ON.
1 -- ”BLEED VALVE” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAUTION
”BLEED VALVE” SWITCH ON MAY CAUSE
OVERTEMPERATURE OR ABNORMAL ACCELERATION
2 -- ”FREON” or “AIR COND” switch (if installed)
OFF
. . . . . . . . . . . .
3 -- If possible, fly to an altitude < 20000 ft
4 -- Air start envelope
CHECKED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Speedwith propeller windmilling
140 < IAS< 190 KIAS
with feathered propeller
IAS > 190 KIAS
5 -- Electrical consumption
REDUCE
. . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -- Power lever
IDLE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 -- Condition lever
CUT OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 -- Tank selector
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .