SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.9.1
Edition 1 -- November 30, 2010
Rev. 0
3.9 -- ELECTRICAL SYSTEM
RED CAS MESSAGE ”BAT OVERHEAT” ON
(if Cadmium--Nickel battery installed)
Indicates a battery overheat
1 -- ”SOURCE” selector
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAS MESSAGE ”BAT OFF”
ON
2 -- Monitor airplane mains battery voltage
3 -- LAND AS SOON AS POSSIBLE
REMARK :
In case of subsequent electrical generator failure, the battery can
be used again by selecting :
4 -- ”GENERATOR” selector
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAS MESSAGE ”MAIN GEN”
ON
5 -- ”SOURCE” selector
BAT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -- Refer to paragraph ”AMBER CAS MESSAGE ”LO VOLTAGE” ON
functioning on ”ST--BY GENERATOR” (after ”MAIN GEN” failure)”
AMBER CAS MESSAGE
“BAT OFF” ON
Indicates that :
-- the ”SOURCE” selector has been positioned on OFF or GPU or
-- the battery plug is disconnected
1 -- If necessary
CORRECT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- If warning persists
SHORTEN FLIGHT
. . . . . . . . . . . . . . . . . . . . . .
3 -- Monitor airplane mains voltage