3.10 -- PRESSURIZATION AND AIR CONDITIONING
AMBER CAS MESSAGE ”VACUUM LOW” ON
Suction gage indicator
CHECK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low vacuum may lead to misfunctioning of leading edge
deicing, pressurization and gyroscopic vacuum--operated
instruments
MONITOR
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary, fly to an altitude
≤
12000 ft and if possible return to VMC