SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.11.1 (a)
Edition 1 -- November 30, 2010
Rev. 0
3.11 -- LANDING GEAR AND FLAPS
DISCREPANCY WHEN
LANDING GEAR GOES UP (1/2)
-- Red warning light on ”LANDING GEAR” control panel remains
ON :
1 -- ”LDG GR” circuit--breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- Landing gear control
DN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -- ”LDG GR” circuit--breaker
PUSH
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
If landing gear is down and locked (correct indication) :
Continue flight if necessary at a speed below 178 KIAS, without
icing conditions or land.
If landing gear does not lock (incorrect indication), refer to
paragraph ”DISCREPANCY WHEN LANDING GEAR GOES
DOWN”.
-- At the end of landing gear up sequence, a green light remains
ON :
1 -- EXTEND landing gear normally.
Then, whatever could be the indication :
2 -- ”LDG GR” circuit--breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -- Floor hatch
OPEN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -- By--pass selector
FULLY PULL / LOCK
. . . . . . . . . . . . . . . . . . . . .
5 -- Hand pump
ACTUATE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
with maximum amplitude
Pre--MOD70--021--32