SECTION 2
LIMITATIONS
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 2.4.1
Edition 1 -- November 30, 2010
Rev. 0
2.4 -- STARTER OPERATION LIMITS
Starter operation sequence is limited as follows :
if Ng
≤
30 %
30 seconds
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
if Ng > 30 %
60 seconds
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Should several sequences be necessary, respect following spacing :
1st sequence
wait
1 minute
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2nd sequence
wait
5 minutes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3rd sequence
wait
30 minutes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4th sequence