SECTION 3
EMERGENCY PROCEDURES
EASA Approved
TBM
700
PILOT’S OPERATING HANDBOOK
Page 3.5.3
Edition 1 -- November 30, 2010
Rev. 0
3.5 -- FIRE AND SMOKE
CABIN ELECTRICAL FIRE OR
SMOKE DURING FLIGHT (1/2)
1 -- Oxygen
USE AS REQUIRED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(pilot and passengers)
If the origin is known :
2 -- Defective equipment
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Descend quickly below 12000 ft
3 -- Using the on board extinguisher (if installed), EXTINGUISH fire if
necessary
4 -- Smoke elimination
(if necessary)
UNDERTAKE PROCEDURE
. . . . . . . . . . . . . . . . . .
(Refer to this chapter)
5 -- LAND as soon as possible
If the origin is unknown :
1 -- ”CABIN FAN” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -- Non essential equipment
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -- Smoke elimination
(if necessary)
UNDERTAKE PROCEDURE
. . . . . . . . . . . . . . . . . .
(Refer to this chapter)
If smoke or fire stops :
LAND as soon as possible.