T B M
PILOT’S OPERATING HANDBOOK
850
SECTION
3
EMERGENCY PROCEDURES
EASA Approved
MISCELLANEOUS
Page
3.13.12
Edition 1 -- June 22, 2007
Rev. 14
3.13 -- MISCELLANEOUS
All
AIRSPEED INDICATING SYSTEM FAILURE
Symptoms : erroneous indication in flight
1 -- ”PITOT L HTR” switch
CHECK ON
. . . . . . . . . . . . . . . . . . . . . . . . .
2 -- ”PITOT R & STALL HTR” switch
CHECK ON
. . . . . . . . . . . . . . . . .
If symptoms persist :
3 -- ”ALTERNATE STATIC” selector
PULL THOROUGHLY
. . . . . . . .
4 -- Use standby instrument only
If symptoms persist, as well as on the airspeed indicator of the L.H
instrument panel, carry out a precautionary approach maintaining an
adequate speed.