Cabin Electrical Fire or Smoke During Flight 2 / 2
► Continuing
15 - Necessary circuit breakers ............................................................ Push
16 - Necessary electrical equipment ....................................................... ON
17 - Defective equipment breaker ........................................................... Pull
18 - Not affected electrical equipment ..................................................... ON
As required
19 - Perform an emergency descent.
Refer to procedure
► Land as soon as possible ◄
End of procedure.
Pilot's Information Manual
Section 3
Emergency Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3.5.5
PIM - DO NOT USE FOR FLIGHT OPERATIONS