3A.9 - Electrical System
BAT AMP
1 / 1
Indicates that battery current is over 50 A while on ground.
After starting the engine with airplane power, a battery charge over 50 A is normal.
CAUTION
Do not take off if battery charge is over 50 A.
If this indication remains steady at a high value:
It may be due to a battery or generation system failure.
End of procedure.
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.9.1
PIM - DO NOT USE FOR FLIGHT OPERATIONS