ICE DETECTION FAIL
1 / 1
Indicates a failure of the ice detector or of the DE ICE SYSTEM panel printed
circuit.
1
- DE ICE SYSTEM mode switch ............................................................... MAN
All deicing systems turn on
NOTE
In case of failure of the DE ICE SYSTEM panel printed circuit, INERT SEP /
AIRFRAME DE ICE / PROP DE ICE / WINDSHIELD systems will be forced to
ON for the remainder of the flight. There is no time limitation to the use of
deicing systems.
End of procedure.
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.11.10
PIM - DO NOT USE FOR FLIGHT OPERATIONS