Airspeed Indicating System Failure 1 / 1
Symptoms: erroneous indication in flight.
1
- PITOT L/R & STALL HTR switch ................................................... Check ON
If symptoms persist:
2
- ALTERNATE STATIC SOURCE selector ....................... Pull thoroughly
3
- Use standby instrument only.
If symptoms persist, as well as on the electronic standby instrument on the
left-side instrument panel:
4
- Perform a precautionary approach maintaining an adequate
airspeed.
End of procedure.
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.12.4