Manual Dry Motoring 1 / 2
To drain fuel accumulated inside the combustion chamber, the FADEC
automatically performs a 30-seconds dry motoring run following an aborted start,
before complete engine shutdown.
During engine shutdown in high OAT, above 24 °C (75 °F), the FADEC
automatically performs a 15-second dry motoring run before complete engine
shutdown.
NOTE
There is no Wet Motoring procedure in the POH.
1
- THROTTLE ............................................................................................. IDLE
2
- ENGINE MODE switch ............................................................................ OFF
3
- IGNITION pushbutton ................................................................ Check AUTO
Status light in blue
4
-
IGNITION
.................................................................................... Check OFF
5
- FUEL TANK SELECTOR ......................................................................... OFF
6
- AUX BP switch ......................................................................... OFF or AUTO
7
-
AUX BP ON
................................................................................ Check OFF
8
-
FUEL PRESS
............................................................................... Check ON
9
- Engine crank mode ................................................................................... ON
To activate the engine crank mode in the dedicated GTC
sub-menu, press: MFD Home, Aircraft Systems, Engine
Crank and then press the crank mode button
10 - Propeller area ........................................................................................ Clear
11 - STARTER switch ....................................................................................... ON
Maintain ON during the motoring sequence
Simultaneously:
12 - Timer clock .............................................................................................. Start
13 -
STARTER
..................................................................................... Check ON
Continue ►
Pilot's Information Manual
Section 4
Normal Procedures
PIM TBM 960 - Edition 0
Rev. 01
Page 4.4.26
PIM - DO NOT USE FOR FLIGHT OPERATIONS