Summary of Contents for ASC1202B-S

Page 1: ...1 Two door One way Access Controller User s Manual V1 0 0...

Page 2: ...tents 1 Overview 1 2 Device Appearance 2 3 Device Installation and Uninstallation 3 3 1 Device Installation 3 3 2 Device Uninstallation 4 4 Port 6 4 2 Cabling 7 4 3 System Structure 9 5 Technical Spec...

Page 3: ...put and output range Do not disassemble the device without professional instruction Please transport use and store the product under appropriate temperature and humidity Warning Please use battery pro...

Page 4: ...owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website for more information...

Page 5: ...2 door sensor 2 vandal proof alarm 2 intrusion alarm 2 It supports 4 groups of output control electric lock 2 alarm output 2 RS485 port may extend to connect to lift control module alarm or household...

Page 6: ...2 Device Appearance Two door one way access controller appearance and dimension are shown in Figure 2 1 Dimension 1 and Figure 2 2 Dimension 2 Unit is mm Figure 2 1 Dimension 1 Figure 2 2 Dimension 2...

Page 7: ...1 Device Installation You can install the device either Fix it on wall with screw Fix it on wall with bracket Installation 1 Fix device on wall with screw as in Figure 3 1 Figure 3 1 Installation 2 F...

Page 8: ...steps Step 1 Fix bracket on wall with screw Step 2 Fasten the device into slot on bracket and pull device downward until it is in place 3 2 Device Uninstallation Uninstallation method for installation...

Page 9: ...5 Figure 3 3 Uninstallation method Step 1 Face screwdriver toward the slot and press it to fasten Step 2 Do it again for second slot and you can take the device down...

Page 10: ...tion 8 Alarm output 2 Unlock Door sensor door 1 9 Dial up switch 3 Unlock Door sensor door 2 10 TCP IP software platform port 4 Alarm input 11 Card reader door 1 5 Lock power output 12 Card reader doo...

Page 11: ...485 3 GND Cabling ports of Unlock Door sensor are as follows Port No Cabling Port Note Unlock Door Sensor 4 PUSH1 Unlock button door 1 5 SR1 Door sensor door 1 6 PUSH2 Unlock button door 2 7 SR2 Door...

Page 12: ...n when outage door 1 16 NO2 Door lock on when outage door 2 17 COM2 Lock power 12V input door 2 18 NC2 Door unlock on when outage door 2 Cabling ports of Alarm Output are as follows Port No Cabling Po...

Page 13: ...or 1 Card Reader 1 485 485 card reader 2 485 3 LED Wiegand card reader 4 D0 5 D1 6 CASE 7 GND Card reader power 8 12V 4 3 System Structure The access controller lock card reader and etc combine a syst...

Page 14: ...ed power 10 15VDC rated current 0 75A Schedule 128 Period 128 Holiday 128 Unlock Mode Card card password password card or password card fingerprint fingerprint password fingerprint or card or password...

Page 15: ...re here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refe...

Reviews: