Local Configurations
174
Parameter
Description
Name
Enter the customized rule name.
Period
Configure the minimum time period for activating alarms by
detecting the abandoned objects.
Filtering Target
Click
to draw areas to filter the target.
You can configure two filtering targets (maximum size and
minimum size). When the target that is crossing the tripwire is
smaller than the minimum size or larger than the maximum size, no
alarms will be activated. The maximum size should be larger than
the minimum size.
Preset
In the
Preset
list, select the preset that you want to configure the
rule for.
Table 5-47
Drag to draw an area.
4)
Click
OK
to save the settings.
5)
Click
to set the actions to be triggered. For details, see "5.11.1.1 Configuring
Step 3
Select the
Enable
check box, and then click
Apply
.
Step 4
The abandoned object detecting function is active. When the object is placed in the
defined detection area for more than the set time, the system activates alarms.
5.11.1.4 Configuring Missing Rules
When the target is taken away from the defined area exceeds the set time, the system activates
alarms.
On the rule line that you added, in the
Type
list, select
Missing
.
Step 1
The
Missing
interface is displayed. See Figure 5-145.
Summary of Contents for DH-5208AN-4KL-X-8
Page 42: ...Connecting Basics 30 Figure 4 2...
Page 94: ...Local Configurations 82 Figure 5 50...
Page 194: ...Local Configurations 182 Figure 5 153 Figure 5 154 Double click the video or click Step 7...
Page 199: ...Local Configurations 187 Figure 5 158 Figure 5 159...
Page 307: ...Glossary 295 Abbreviations Full term VGA Video Graphics Array WAN Wide Area Network...
Page 325: ...Earthing 313...