User’s Manual
211
Trigger
Configure the triggering parameters.
Table 5-37
Triggering parameters
Parameter
Description
Schedule
Define a period during which the detection is active.
For details, see "Setting Motion Detection Period" section in "5.10.4.1
Configuring Motion Detection Settings".
Alarm-out Port
Click Setting to display setting page.
General Alarm: Enable general alarm and select the alarm output
port.
Ext. Alarm: Connect the alarm box to the Device and then enable it.
Wireless Siren: Connect the wireless gateway to the Device and then
enable it. For details, see "5.12 IoT Function".
When an alarm event occurs, the system links the peripheral alarm devices
connected to the selected output port.
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300
seconds. If you enter 0, there will be no delay.
Show Message
Select the Show Message checkbox to enable a pop-up alarm message
in your local host PC.