20
3 Installation
Important
Before you complete the installation and setup, do not remove the electrostatic attraction
film on the transparent enclosure. Otherwise it may result in injury.
After remove electrostatic attraction film, do not touch dome enclosure in case it may leave
stain.
Before the installation, please make sure the ceiling can sustain at least 20 Kg.
The network camera can be placed horizontally on table to monitor, or installed on bracket
or in ceiling. Please refer to following sections.
3.1 Device Installation Introduction
Please refer to Figure 3-1 for device installation space information. We recommend you install the
device on ceiling with hole diameter of
Φ146~Φ150mm, and ceiling thickness of 10 ~25mm.
Figure 3-1 Installation diagram
3.2 Device Installation Steps
3.2.1 General Installation
Step 1
Take the installation position map from the accessories bag and then paste it on the installation ceiling
or the wall according to the monitor area. Please dig
installation holes with diameter of Φ146~Φ150mm.