User's Manual
273
Table 8-25 Thermal alarms
Function
Description
Fire alarm
When the thermal camera detects a fire, the alarm signal is transmitted
to the Device, which performs an alarm linkage action.
Temperature alarm
When the thermal camera detects that the temperature is above or
below the threshold value, the alarm signal is transmitted to the Device,
which performs an alarm linkage action.
Temperature
difference alarm
When the thermal camera detects a temperature difference greater than
the set value, the alarm signal is transmitted to the Device, and the
Device will perform an alarm linkage action.
Hot spot alarm
When the maximum temperature detected by the thermal camera is
higher than the set value, the alarm signal is transmitted to the Device,
and the Device will perform an alarm linkage action.
Cold spot alarm
When the lowest temperature detected by the thermal camera is below
the set value, the alarm signal is transmitted to the Device, and the
Device will perform an alarm linkage action.
This section uses the procedure of configuring fire alarm as an example.
Step 1
Click
, or click
on the configuration page, and then select EVENT.
Step 2
Select the root node in the device tree on the left.
Step 3
Select Thermal Alarm > Fire Alarm.
Step 4
Click Deployment Time to select schedule from the drop-down list.
After setting deployment period, system triggers corresponding operations when there is
a motion detection alarm in the specified period.
●
Click View Schedule to view detailed schedule settings.
●
If the schedule is not added or the added schedule does not meet actual needs, click
Add Schedule. See "8.8.4 Schedule" for detailed information.
Step 5
Click Actions to set alarm actions. See "8.4.1 Alarm Actions" for detailed information.
Step 6
Click Save.
8.5 Storage Management
Click
or click
on the configuration page, select STORAGE. The Local Hard Disk page is
displayed. Manage storage resources (such as recording file) and space, so you can use and improve
utilization ratio of storage space.
The system supports pre-check and routine inspection, and displays health status, so you can obtain
real-time status of device and avoid data loss.
●
Pre-check: During device operation, the system automatically detects disk status in case of
change (reboot, insert and pull the disk).
●
Routine inspection: the system carries out routine inspection of the disk continuously. During
device operation, the disk might go wrong due to service life, environment and other factors.
Find out any problems during routine inspection.
Summary of Contents for IVSS
Page 1: ...IVSS User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V6 0 0...
Page 30: ...User s Manual 10 2 2 3 Dimensions Figure 2 12 Dimensions mm inch...
Page 37: ...User s Manual 17 2 3 3 Dimensions Figure 2 21 Dimensions with LCD mm inch...
Page 38: ...User s Manual 18 Figure 2 22 Dimensions without LCD mm inch...
Page 45: ...User s Manual 25 2 4 3 Dimensions Figure 2 31 Dimensions with LCD mm inch...
Page 46: ...User s Manual 26 Figure 2 32 Dimensions without LCD mm inch...
Page 47: ...User s Manual 27...
Page 68: ...User s Manual 48 Figure 5 9 Login web 5 4 Home Page Figure 5 10 Home page...
Page 129: ...User s Manual 109 Figure 6 29 Human...
Page 309: ...User s Manual...
Page 310: ...IVSS User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V5 0 2...
Page 351: ...User s Manual 22 Figure 2 32 Dimensions without LCD mm inch...
Page 670: ...User s Manual 341 Figure 11 2 Unlock the client...
Page 685: ...User s Manual...
Page 686: ...IVSS7008...
Page 687: ...2 3 1 1 1 2 1 4 1 3 1 2 2 1 2 1 2 2 IVSS7012...