2.2
Debugging Of Human Body Temperature Detection Function
2.2.1
Selection of human body temperature measurement intelligent scheme
2.2.2
Blackbody Parameter Setting
➢
Blackbody calibration.
Note: the blackbody parameter setting steps are ignored for the scheme without blackbody.
a)
When the blackbody is actually set to 35
℃
, there may be three situations on the back of the blackbody,
one is the digital tube display (right two), the other is the LCD display (left):
Note
:
For the blackbody display of the LED, just press the bottom
‘︿’
‘﹀’
to adjust the value; for
the LCD display device, press the bottom
‘
<’ to select the value to be adjusted, and then press the
bottom
‘︿’
‘﹀’
to adjust the value.
b)
After fixing the camera and the blackbody position, make sure that the blackbody is on the right or left
side of the image and is not blocked (the best position of the blackbody: put it on the top left or the
middle position of the ‘Cross type’ on the top right: as shown below)