background image

Preface    I 

Preface 

Summary 

The  temperature  of  all  materials  is  higher  than  absolute  zero  (-  273.15 

)  and  radiates 

electromagnetic wave continuously. The thermal imaging camera collects the infrared radiation energy 
emitted  by  the  measured  objects, and  establishes the  accurate  corresponding  relationship  between  the 
target  energy  and  temperature  through  complex  temperature  measurement  algorithm  and  blackbody 
temperature measurement calibration and other processes, so as to realize the temperature measurement 
function  of  human  body.  It  is  characterized  by  non-contact,  multi-objective,  fast,  and  no  risk  to  the 
temperature measurer. It can be easily deployed in densely populated public places, and it can effectively 
and safely screen the abnormal temperature preliminarily. 

Thermal imaging human body temperature measurement, mainly through the measurement of human 

forehead and face temperature (according to the different environment of about 31-36 

), preliminary 

judgment, found that the suspected abnormal temperature, and then use ear temperature gun or mercury 
thermometer  to  further  confirm. As  the  skin  surface  of  forehead  and  face  is  exposed  to  the  air,  the 
temperature  changes  due  to  the  influence  of  air  flow  and  sweat.  Generally,  under  the  indoor  ambient 
temperature of 15 

  in winter, if the forehead temperature exceeds 35 

, there is a possibility of fever. 

For other environmental temperature conditions, it is recommended to measure several samples on site, 
and increase 1 

  as the alarm threshold on the basis of normal forehead temperature. 

The  human  body  temperature  measurement  requires  high  precision,  which  requires  high 

installation mode, environment and debugging. Please read this article carefully. 

Combined with the support experience of the thermal imaging R & D technical support team, 

this manual describes the installation requirements, common operations and precautions during the actual 
use of thermal imaging products, so as to facilitate the quick start and reduce unnecessary problems. For 
more detailed instructions, please refer to the product manual and quick operation manual. 

The content described in this article needs to be analyzed in combination with the actual field equipment, 
which is not the only way. If you have any questions or good suggestions, please contact Xu Fangrong 
(Short NO: 693802), Fang Lu (Short NO: 685718), Li Fuxiang (Short NO: 638137), Fang Shengdong 
(short: 669126). 

 

 

This manual is only for internal use of Dahua employees. Please do not directly provide it to 
customers or publish it to public platforms such as the Internet. 

 

Reading objects include (but not limited to): Solution Engineer, Pre-sale / in-sale / after-sale technical 
support engineer, installation and debugging personnel, product engineer, test engineer, marketing 
and sales personnel and other internal personnel of the company 

 

 

 

Summary of Contents for BF Series

Page 1: ...Dahua Thermal Body Temperature Measurement Solution Installation Guide BF Series Zhejiang Dahua Technology Co Ltd...

Page 2: ...ture exceeds 35 there is a possibility of fever For other environmental temperature conditions it is recommended to measure several samples on site and increase 1 as the alarm threshold on the basis o...

Page 3: ...Preface II Change Record Revision date Version number Creater Reviser 2020 01 27 V1 0 2020 01 28 V1 1 2020 01 31 V1 2 2020 02 03 V1 3...

Page 4: ...2 General Settings 7 2 1 Equipment Upgrade 7 2 2 Debugging Of Human Body Temperature Detection Function 8 2 2 1 Selection of human body temperature measurement intelligent scheme 8 2 2 2 Blackbody Par...

Page 5: ...nd other requirements The PPT version of installation guidance video web operation guidance and guidance document should be obtained from the regional delivery supervisor In the future it will be sync...

Page 6: ...by one at the designated position BF5421 13mm installation requirements are consistent with BF3221 7mm 1 3 Installation Diagram BF3221 3 5mm installation diagram Blac kbod y Height 2m Side view h u m...

Page 7: ...objects 3m Height of Blackbody 1 8m Thermal camera focal length 13mm Blac kbod y Sidewalk width 1 5m Top view Thermal camera focal length 13mm 1 4 Scene Diagram BF3221 7mm as an example Distance betwe...

Page 8: ...Height of Blackbody 1 8m Personnel access direction 1 When the artificial diversion channel is lengthened as far as possible multiple S shaped can be used When the indoor and outdoor temperature diffe...

Page 9: ...e facing the camera irradiation direction the black body shall be on the left or right side of the thermal imaging picture and the tripod can be protected by temporary fence As follows blackbody is in...

Page 10: ...tified in the delivery group please pay attention to the group information in time The default to be restored after upgrading is as follows Note 1 If temperature compensation has been carried out in 2...

Page 11: ...blackbody one is the digital tube display right two the other is the LCD display left Note For the blackbody display of the LED just press the bottom to adjust the value for the LCD display device pr...

Page 12: ...fter drawing the wireframe should be drawn along the edge of the bright area before 20200210 the wireframe should be in the middle of the blackbody the smaller the wireframe the higher the measurement...

Page 13: ...in the figure below indicates that an audible and visual alarm will be generated when the head temperature of the subject exceeds 37 3 When the capture angle filter value is 1 only the front side simi...

Page 14: ...e Thermal Camera Face Frame Camera settings camera properties channel 2 find binocular calibration adjustment adjust the up down left and right arrows set step length according to the actual situation...

Page 15: ...12 3 Announcements The following is for blackbody Warning A warning indicates a condition that may cause harm to the user To avoid personal injury or instrument...

Page 16: ...iation strong electromagnetic interference and vibration Heat dissipation space shall be reserved around the blackbody and the distance from the surrounding objects shall not be less than 10cm Calibra...

Page 17: ...nt is 10 30 6 The best distance for temperature measurement The best temperature measurement distance is the same as the distance between blackbody and equipment 3 5mm detection distance is 2m and the...

Page 18: ...tion alarm Select event management blackbody exception alarm blackbody exception enable and turn on or off The default sensitivity is 60 and the lower the value the less likely it is to report blackbo...