10
Parameter
Description
Emissivity
The default value is 0.97.
Distance
The distance between the measuring target and the Camera.
Make sure that the actual distance is consistent with this value, otherwise
the accuracy will be affected.
Unit
Temperature unit: °C, °F and K. You can switch the temperature unit by
pressing
.
Press
to save your configurations and quit.
Temperature Measurement Settings
The Camera supports temperature measurement. An alarm will be triggered when the temperature of
the measured target exceeds the alarm threshold.
On the live interface, press
to enter the
Menu
interface.
Press
Temp Measurement
.
Configure temperature measurement parameters.
1)
Press
/
to select parameters.
2)
Press
to confirm.
3)
On the parameter configuration interface, press
/
to increase or decrease the
parameter value.
Table -5 -2 Parameter description of temperature measurement
Parameter
Description
Alarm Settings
Threshold
: An alarm will be triggered when the temperature of the
measured target exceeds the defined alarm threshold. On the live
interface, the temperature that exceeds the alarm threshold flashes
and is displayed in red.
Snapshot
: Whether to enable snapshot when an alarm is triggered.
Buzzer
: Whether to beep when an alarm is triggered.
Enabling snapshot or buzzer will reduce the battery life of the Camera.
Temp Correction
The measured temperature and the actual values might not be the same
due to many factors. You can select multiple objects for testing, and then
correct the temperature deviation according to the results. For example:
If the measured temperature is 0.5 °C (41
°
F) lower than the actual
temperature, the correction value is configured to 0.5 °C (41
°
F);
If the measured temperature is 0.5 °C (31.1
°
F) higher than the actual
temperature, the correction value is configured to
–
0.5 °C (31.1
°
F).
Press
to save your configuration and exit.