IV
Use power supplies that meet ES1 but do not exceed PS2 limits defined in IEC 62368-1. For
specific power supply requirements, refer to device labels.
Connect the Device (type-I structure) to the power socket with protective earthing.
The appliance coupler is a disconnection device. Keep at a convenient angle when using it.
Precautions
Pass the turnstile as soon as possible after authorization. The arms will be closed after a
specified time.
When multiple people are entering, the continuous authorization interval is ≥ 1 s.
Pay attention to the indicator of the turnstile. If it is a green arrow, passing in this direction is
allowed; if it is a red cross, passing is not allowed.
The turnstile supports anti-trailing and anti-reverse intrusion functions. If you force your way
into the passage, the turnstile will lock the arms, which might result in personal injury.
The turnstile will not correctly recognize an authorized card if it is used with other cards.
Keep the authorized card safe to make sure it works properly.
Do not move anything through the turnstile, otherwise, the turnstile will consider it
unauthorized.
If the turnstile is to be installed outdoors where water pooling is likely to occur, it must be
installed on a 50 mm–150 mm cement base (adjust as needed). The passage also should be
elevated to the same height of the cement base. Apply silicon sealant to the gap between the
cement base and the turnstile to keep water out and condensation.