Local Basic Operation 192
3) Configure the parameters. See Table 4-31.
Table 4-31
Parameter
Description
Name
Customize the rule name.
Action
Set the intrusion action, including appear and crossing area.
Direction
Set the direction to cross the area, including enter, exit and both.
Filter target
Click
to filter the target. Check the blue wireframe and adjust the size of
the area with the mouse.
Each rule can set 2 target filters (maximum size and minimum size), that is,
when the passing target is smaller than the minimum target or larger than the
maximum target, no alarm will be generated. The maximum size should not
be smaller than the minimum size.
AI recognition
Select AI recognition and the system displays alarm target. The default
selection is person and motor vehicle and system automatically identifies the
person and motor vehicle appeared within the monitoring range.
4) Press and hold down the left button on the monitoring screen to draw the
monitoring area.
5) Click
OK
to complete the rule setting.
Step 3 Click
, you can refer to the
to set other parameters.
Step 4 Select the
Enable
check box and click
Apply
to complete the intrusion setting.
4.7.2.4.3
Abandoned Object Detection
System generates an alarm when there is abandoned object in the specified zone.
Step 1 In the
Type
drop-down list, select
Abandoned Object.
The interface is shown as Figure 4-134.