142
Parameter
Function
Period
This function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to
enable corresponding period.
Select date. If you do not select, current setup applies to
today only. You can select all week column to apply to the
whole week.
Click OK button, system goes back to local alarm
interface, please click save button to exit.
Type
Normal open or normal close.
Trigger
Here is for you to set activation mode. There are two
options: High/low. Select high if the alarm signal is
12V/24V voltage. Select low if the alarm signal is the GND.
Overlay
Please highlight the box here to enable this function. It can
overlay alarm information on the video screen when an
alarm occurred.
Anti-dither
System only memorizes one event during the anti-dither
period. The value ranges from 5s to 600s.
Record channel
System auto activates channel(s) to record once an alarm
occurs.
Note
Make sure you have enabled motion detect alarm
record function. Refer to chapter 5.6.4.1 Schedule for
detailed information.
Make sure you have enabled auto record. Refer to
chapter
Record
control
for
detailed
information.
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Alarm out
Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.
Latch
System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
Show message
System can pop up a message to alarm you in the local
host screen if you enabled this function.
Buzzer
Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
Log
Check the box here, system can record local alarm event
log.
Alarm upload
System can upload the alarm signal to the center
(Including alarm center.
Send Email
If you enabled this function, System can send out an email
to alert you when an alarm occurs.