80
Figure 4-71
Sensitivity: This item is for motion detect and tampering only. System supports 6
levels. The sixth level has the highest sensitivity.
Delay motion: Check the box to delay motion detect function. This function becomes
valid when ACC OFF.
Alarm output: when an alarm occurs, system enables peripheral alarm devices.
Latch: when video loss is complete, system auto delays detecting for a specified
time. The value ranges from 1-300(Unit: second)
Show message: System can pop up a message to alarm you in the local host
screen if you enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
center) if you enabled current function.
Send email: System can send out email to alert you when an alarm occurs.
Record channel: Select the channel to activate recording function once an alarm
occurred.
Note
Make sure you have enabled alarm record function. Refer to chapter 4.1.6
Schedule for detailed information.
Make sure you have enabled auto record. Refer to chapter 4.1.5 Record for
detailed information.
Record Delay: System can delay the record for specified time after alarm ended.
The value ranges from 10s to 300s.
Tour: Here you can enable tour function when an alarm occurs. System one-window
tour. Please go to chapter 4.2.1.4.2 Tour for tour interval setup.
Snapshot: You can enable this function to snapshot image when detect alarm
occurs.
Note
Make sure you have enabled trigger (event) snapshot. Refer to chapter
4.3.1.2.3 Snapshot for detailed information.