Local Configurations
98
Illegal Login: When the times of consecutive user name or password input errors
exceed the set number, the account is locked and the system generates alarm and
link the configured actions.
Select the
Enable
check box.
Step 3
Configure the parameters. For details, see Table 4-35.
Step 4
Table 4-35 Abnormal event setting parameters description
Parameter
Description
Less Than
If
HDD No Space
is selected, configure this parameter.
In the Less Than box, enter the minimum HDD space percentage. If the
HDD space becomes less than this number, the system activates alarm.
Threshold
If
Temperature Too High
is selected, configure this parameter.
In the
Threshold
box, enter the maximum internal temperature of Device.
Battery
Voltage
If
Battery Low Voltage
is selected, configure this parameter.
In the
Battery Voltage
boxes, enter the minimum percentage of supply
voltage and supply voltage to the Device from vehicle.
Max Speed
If
Over Speed
is selected, configure this parameter.
In the
Max Speed
box, enter the maximum driving speed of vehicle.
Min Speed
If
Low Speed
is selected, configure this parameter.
In the
Min Speed
box, enter the minimum driving speed of vehicle.
Threshold
If
Rapid Speedup
is selected, configure this parameter.
In the
Threshold
box, enter the maximum acceleration value of vehicle.
Threshold
If
Rapid Slowdown
is selected, configure this parameter.
In the
Threshold
box, enter the maximum deceleration value of vehicle.
Attempt(s)
If
Illegal Login
is selected, configure this parameter.
In the
Attempt(s)
box, enter the maximum number of allowed password
input errors. If the number of password input errors reaches this value, the
user account will be locked.
Lock Time
If
Illegal Login
is selected, configure this parameter.
If the number of password input errors reaches the set value, the user
account will be locked.
Alarm Output
Connect the alarm device such as light and siren to the alarm output port.
Select the check box of Alarm Out to enable the alarm linkage. When an
alarm event occurs, the system links the alarm device to activate alarm.
Latch
Set a length of time for the Device to delay turning off alarm after it is
canceled. The value ranges from 1 second through 300 seconds.
Show
Message
Select the
Show Message
check box to enable a pop-up message in your
local host PC when an alarm event occurs.
Snapshot
Select the
Snapshot
check box and select a snapshot channel(s). When an
alarm event occurs, the corresponding channel starts capturing
automatically.
You can also configure the frequency, size, and quality of snapshot. For
details, see "4.3.1.2.3 Configuring Snapshot Settings."