58
Auto
parameter.
The supply voltage to the device from the vehicle and the percentage of available
supply voltage capacity. When the vehicle is in ACC Off, and the voltage supplied
to the device is less than the percentage of available capacity, the system triggers
an alarm.
Accumulator
voltage
Max speed
Select
Device
tab, and if the
Event Type
is
Over Speed
, configure this parameter.
The upper limit of vehicle speed. When the vehicle speed exceeds this value, the
system triggers an alarm.
Min speed
Select
Device
tab, and if
Event Type
is
Low Speed
, configure this parameter.
The lower limit of vehicle speed. When the vehicle speed is lower than this value,
the system triggers an alarm.
Rapid
acceleration
threshold
value
If
Event type
is
Rapid
Acceleration
, configure this parameter.
When vehicle speed rapidly accelerates during short time period to exceed this
value, the system triggers an alarm.
Rapid
deceleration
threshold
value
If
Event type
is
Rapid Deceleration
, configure this parameter.
When vehicle speed rapidly decelerates during short time period to exceed this
value, the system triggers an alarm.
Alarm output
Connect the alarm device such as light and siren to the alarm output port. Select
the corresponding check box and set an alarm output device. With the alarm
linkage output port enabled, when an alarm event occurs, the system links the
alarm device to trigger an alarm.
Latch
Click
Setting
under
Alarm Out
to set the latch.
Set a length of time during which the device continues alarm output after the
alarm ends.
Show
message
Click
More
, and select the corresponding check box to trigger a pop-up message
in your local host PC when an alarm event occurs.
Send email
Click
More
, and select the corresponding check box. When an alarm event occurs,
the system sends email to the specified mailbox.
Set your e-mail first before enabling this function.
Buzzer
Click
More
, and select the corresponding check box to trigger a buzzer noise on
the device when an alarm event occurs.
System log
Click
More
, and select the corresponding check box to enable the device to
create a local alarm log when an alarm event occurs.
Refresh
Select the
Refresh
check box. If No Disk alarm occurs, the system restarts within
three minutes.
Click
OK
.
5.1.4
Configuring Alarm Out Settings
You can set the alarm output type.
On the main web interface, select
ALARM > Alarm Mode
.
The