57
EZoom
Enlarge the thermal image according to the zoom time you
have set.
ROI Type
Select the district of strengthening video quality. The
brightness and clarity of the chosen district will be higher.
District consists of 25% central point, 50% central point, 75%
central point, full screen, bottom part, middle part, above
part and user-defined part.
When you set
ROI Type
to
Custom
, you need to press and
drag the left mouse button. Then, add the "ROI Type" box.
Mirror
Open the mirror image and the monitor image will reverse
from left to right.
Picture Freeze
When you are using the preset, the preset image that has
been used will be directly represented. The image during the
movement of PTZ will not be displayed.
Basic NR (Noise
Reduction)
Average the pixel of single frame image with other pixels to
reduce the image noise.
Select the copy frame, open the basic noise reduction and
configure the class of basic noise reduction. The higher the
class, the better the noise reduction, but the image will be
less clear.
Gain settings
Auto Gain
The larger the gain value, the more unstable the image.
Balanced Gain
The larger the district, the bigger the contrast.
Gain Mode
Low-temperature mode and high-temperature mode are
contained.
FFC Settings
FFC Mode
Method of correcting the shutter.
Auto: According to the switch period that you have
configured, the shutter will be corrected regularly.
Manual: Correct the shutter by yourself.
FFC Period
You can configure this parameter only when
FFC Mode
is set
to be
Auto
.
Adjust time gap of correcting the shutter automatically.
Do FFC
Click
Do FFC
to trigger the shutter correcting for this time.
Click
Save
.
Step 4
Click
Reset
and the lens properties are restored to the primary state.
4.1.1.3
Configuring Profile Management
When configuring the profile management, you can select from
Normal
,
Full Time
and
Schedule
.
Select
Setting > Camera > Conditions > Conditions > Profile Management
.
Step 1
The Profile Management interface is displayed.
Profile management configuration:
Step 2
When
Profile Management
is set as
Normal
, the surveillance system works under
normal configuration.