High  Performance  Dry  Bath  Heating  &  Cooling

                                                                                   

26/48

Maintenance                                   

12

1. Be sure to operate the unit only with the specified power supply

(AC 120, 60Hz or AC 230V, 50/60Hz, Single phase)

2. Do not use this unit when temperature fall below 5

°

C and rise above 40

°

C.

3. If you don’t use the unit for a long time, please plug out, dry up the unit and keep 

with packing.

4. When  the  unit  is  needed to  replace a  component  for  repair,  you  MUST  use  an  original 

component provided by manufacturer.

5. In the warranty period specified on the warranty sheet included in this operation manual, 

breakdown of the unit in spite of normal/proper use will be treated by manufacturer or by 

an official agent of manufacturer. 

6. The manufacturer or its agent is not in charge of breakdown caused by abnormal use or by 

ignoring the warnings and cautions described in this manual.

7. Before cleaning the unit, please be sure to pull the power cord off.

8. For cleaning of the unit, we recommend you to use neutral detergent and soft cloth. Do not 

use coarse cloth, strong chemicals or organic solution.

Summary of Contents for HB-R48

Page 1: ...ied PL Insurance Patented No 10 0554098 Jog Shuttle Control System Operation Manual Version 2 1 1 written for HB R48 HB 96 HB 96D models HB 48 High Performance Dry Bath Heating Sales Basic A S By the...

Page 2: ...o which this declaration relates is in conformity with the following standard or other normative document EN 61326 EN 61000 3 2 EN 61000 3 3 EN 61010 1 EN 61010 2 following the provisions of the direc...

Page 3: ...R48 to which this declaration relates is in conformity with the following standard or other normative document EN 61326 EN 61000 3 2 EN 61000 3 3 EN 61010 1 EN 61010 2 following the provisions of the...

Page 4: ...oling 4 48 Contents Page 1 Safety Instructions 5 2 Before Use 9 3 Introduction 10 4 Package Contents 11 5 Appearance and Naming 12 6 Installation 13 7 Cautions in Use 15 8 Controller Details 17 9 Oper...

Page 5: ...indicates the risk of explosion or fire This symbol indicates the user must be kept away while operation This Symbol indicates that this product is to be collected separately The following apply only...

Page 6: ...electric shock or a short circuit to each part Do not connect wrong electricity since it is the cause of a fire Disconnect the power supply plug if the unit is not going to be used for an extended per...

Page 7: ...the holes on the side or rear surface of the body are not blocked by a wall or an object And do not operate the unit at a poor ventilated place or use closed It may cause a fire or damage of the unit...

Page 8: ...rer or a supplier CAUTION This unit must be connected to an earthed power supply If you use radiation or contaminated samples the responsibility is to the customer Do not use this product to steriliza...

Page 9: ...cation of exterior or specifications could be made without notice to improve the quality and performance of the product Product Liability PL Insurance Admission DAIHAN Scientific Co Ltd is a member of...

Page 10: ...ubator and Other Laboratory Procedures Precise Temperature Control 0 1 at 37 0 2 at 90 0 4 at 135 HB 96D Precise Temperature Control 5 95 with 0 15 Accuracy HB R48 User s Self Compensation Function fo...

Page 11: ...HB R48 unit 1 5ml Block 48 holes HB R48 Set HB 96D Set Acrylic Lid HB R48 Set HB 96D Set Extraction Tongs BLE101 HB R48 Set 96D Set Power Cord HB R48 Set HB 96D Set Manual Package Set Unit 1 5ml bloc...

Page 12: ...nclude various model for its usage The appearances of High Performance Cooling Series are shown in Figure 1 Figure 2 The appearance of HB 96D Set with Block for 1 5ml X 48tubes X 2ea Individual chambe...

Page 13: ...t WARNING Place the unit on a level horizontal surface to support the capacity of the unit without vibration If there is vibration install the unit on a support material with enough space Small place...

Page 14: ...ing The unit should be set at a well ventilated place Be sure the holes on the side or rear surface of the body are not blocked by a wall or an object And do not operate the unit at a poor ventilated...

Page 15: ...is generated pull out the mains plug and contact manufacturer or a supplier Do not put any objects insides When an object that is easy to be combustible like a stone a metal or paper goes insides it m...

Page 16: ...you don t have to be worried If you use the unit for the purpose of heating external object by circulation circulation distance should be shorter than 7m and extension tube as thick as possible is re...

Page 17: ...o Table 1 Setting the value of Temperature or Timer by Turing Heating Lamp during heating Start and stop by Pushing Timer Lamp Indication of Set Timer HB R48 96D models has same structure Set Mode Upp...

Page 18: ...g MODE button Refer to Figure 5 The three modes are 1 Timer Mode Set Operation Time mode 2 Temperature Mode Set Temperature mode 3 Safety Mode locking Mode and the sub modes are Delay Mode Set Delay T...

Page 19: ...present value of the timer Initial SV of the timer is 00 00 which means infinite time and the unit will operate heating or cooling continuously once the operation start Turn the Jug Shuttle Knob such...

Page 20: ...onds When you finish Set Value push Jog shuttle Knob About in 2 3 seconds will be save the Set Value of Temperature After that push the Jog shuttle Knob 1time shortly the heater will be running After...

Page 21: ...nd Jog shuttle knob together i e push Jog shuttle knob while pushing MODE button at the same time in Set Temperature mode l PV on LCD display indicates current temperature and the SV indicates the Off...

Page 22: ...button 1 time 8 Storage of the Set Value High Performance Dry Bath Heating Cooling Block has Memory function to save each set value The user can save the set values to be used frequently and does not...

Page 23: ...ube 30 holes Optional DH WHB521628 Block BLT628 16 5 Test Tube 24 holes Optional DH WHB521828 Block BLT828 18 Test Tube 24 holes Optional DH WHB5315158 Block BLC515 15ml Conical Tube 15 holes Optional...

Page 24: ...DAIHAN Sci com or ALL forLAB com Shopping Mall High Performance Dry Bath Heating Cooling 24 48 Specifications 11...

Page 25: ...DAIHAN Sci com or ALL forLAB com Shopping Mall High Performance Dry Bath Heating Cooling 25 48...

Page 26: ...repair you MUST use an original component provided by manufacturer 5 In the warranty period specified on the warranty sheet included in this operation manual breakdown of the unit in spite of normal p...

Page 27: ...e shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This certification is on...

Reviews: