(38) Remove the radiator cap.
(39) Ensure that the concentration of antifreeze solution in
the radiator meets the instruction of the manufacturer
of antifreeze solution by a densitometer.
Adjust the concentration of the antifreeze solution in
the radiator according to the instruction of the manu-
facturer of the antifreeze solution, if the concentration
does not meet the instruction of the manufacturer of
the antifreeze solution.
(40) Secure the radiator cap.
(41) Drain the water in the reserve tank.
(42) Pour the coolant which is mixed with antifreeze solu-
tion and water in accordance with the instruction of the
manufacturer of the antifreeze solution.
(43) Secure the reserve tank cap.
MA–25
JMA00070-00054
JMA00071-00055