11
-
6 CONNECTION PROCEDURE
WARNING
Follow the instructions below to avoid electric shock.
Do not touch live electrical parts, as this may cause in fatal shock and severe burns.
•
Do not touch live electrical parts of the welding machine.
•
Have a qualified electric engineer ground the case of the welding power source and the base metal
or jig electrically connected, following a local low.
•
Disconnect the wire feeder from the welding power source by turning off the line disconnect switch
in the power box to avoid an electric shock before grounding the welding power source or base metal
and connecting the cables or hoses.
•
Do not use a cable with lack of capacity or a damaged cable.
•
Tighten and insulate the connections of cables.
•
Firmly attach the cover of the welding machine after connection of the cables.
•
Do not place the welding power source, wire feeder, torch, and control cable (including the extension
cable) in an area where the equipment can become wet.
•
Insulate connected part of the bolt and the nut with the insulating tape surely after it tightens enough.