7-15
Chapter 7
Administrator F
unctions
D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
1.
Turn on the power switch.
2.
Insert the USB flash drive to the USB connector of the operation panel.
3.
Press the LOAD key.
4.
Turn the parameter adjusting knob counterclockwise to display "USb" on the left digital meter.
5.
Select the data to back up.
6.
Press the LOAD key.
7.
Press the ENTER key.
⇒
The LED of LOAD key lights up.
●
Turn the parameter adjusting knob further
counterclockwise to display the data to backup on
the right digital meter.
⇒
The display changes in order of "ALL" -> "1" -> "2" -
> "3" -> "4".
⇒
"ALL" means that all the data ("1" to "4") available for
backup are selected.
⇒
Details of the numbers displayed (
⇒
The LED of ENTER key flashes.
⇒
Data backup starts. During backup, the display of
right digital meter changes.
⇒
When backup is completed, "End" will be displayed
on the right digital meter.
⺒
LOAD
LOAD
A
V
s
㸣
m/min.
sec.
JOB No.
Hz
LOAD
ENTER
㧔
3 sec.
㧕
A
V
s
㸣
m/min.
sec.
JOB No.
ENTER
㸦
3 sec.
㸧
Hz