M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-10
6.5 Memory Function of Welding Conditions
This section explains the memory function of welding conditions.
The welding power source is equipped with the function to register the welding conditions and reads
them out for use. The number of welding conditions that are able to be registered are 100 at maximum.
Single welding condition can contain the following information at registration:
•
Welding mode selected by the keys on operation panel (Shielding gas/Wire/Crater/Penetration control,
etc.)
•
Welding current/voltage for each welding sequence (
-
•
Part of internal function (
NOTE
• When the analog remote control is connected to the machine, even if the stored welding
condition is read, the set values of the analog remote control apply to the welding current
and welding voltage of welding condition.
T I P S
• Use of the internal function (F44) enables to read out the registered welding condition by the
analog remote control (optional). (
-
• Use of the internal function (F11) enables to finely adjust the current/voltage values read out
from the memory by the analog remote control (optional). (
-
• The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the
stored contents may be changed or lost. BE SURE TO MAKE A COPY FOR IMPORTANT
DATA.
• Please note that OTC will not be liable for any alteration or loss of electronic
information.