SFLC-212-173
18
4.3.5 Setting mode
Various kinds of setting are performed. Setting mode is three types, and operations are different.
DISPLAY is pushed in case it returns to the original measurement display. And, if a switch is not operated
for 10 minute after a set point check, it will return to the original measurement display automatically.
Operation and the contents of setting (detail) in setting mode, please refer to "5 Setting".
・Setting mode 1:Press SET for longer than 3 seconds.
・Setting mode 2:Press SET and RESET/SHIFT together for longer than 3 seconds.
・Setting mode 3:Press SET and DISPLAY together for longer than 3 seconds.
<Reference> A measurement display and maximum display,minimum display can also perform this operation.
Setting mode 2
New setting
Current setting
Setting No.
Setting factor
SET 3 seconds
SET + RESET/SHIFT 3 seconds
SET + DISPLAY 3 seconds
DISPLAY
A(V) display
Setting mode 1
New setting
Current setting
Setting No.
Setting mode 3
New setting
Current setting
Setting No.
V(UV) display Wh display
W display
Measurement display
Return to
measurement
display