background image

SVD-208-053 

 

 
 ■ LL type 

Power and input 

conditions. 

Drawing of input state. 

Contact status 

LED indication status 

(At contact operating, ON) 

L2 

L1 

Power OFF 

L2

0

F.S

L1

 

10

9

11

 

2

1

3

 

OFF

OFF

L2

L1

 

Power ON 
Input ≦ L2 

L2

0

F.S

L1

 

10

9

11

 

2

1

3

 

ON

OFF

L2

L1

 

Power ON 
L2 < Input < L1 

L2

0

F.S

L1

 

10

9

11

 

2

1

3

 

OFF

ON

L2

L1

 

Power ON 
L1 ≦ Input  

L2

0

F.S

L1

 

10

9

11

 

2

1

3

 

OFF

OFF

L2

L1

 

 
 
3. Handling explanation 

3.1 Outline dimension  

 

 
 
 
 
 
 
 

3.2 Installation 

The environmental conditions of installation 
space.  Please select indoors without low 
mechanical vibration, dust, and corrosive gas.  
And, please select indoors without the 
influence of the strong electric magnetic 
field by the large current bus, saturable 
reactor.   
Please prepare the installation interval more 
than the right figure in consideration of 
radiation by the natural convection of air. 
If the duct for wiring is used, please detach 
20mm or more from the upper surface and the 
undersurface of a body.  
A mounting instruction can select 35mm width 
DIN rail mounting and screw mounting.   
In screw mounting, please install with M4 
screw.   
However, the screw is not attached.  The tightening torque of a screw, M4:1.08~1.47N・m(11~15kg・cm) 

 

 

Setting switch (1) 

Setting switch (2) 

HH 

H1 

H2 

LL 

L2 

L1 

HL 

H  

― 

L  

― 

● Mounting dimension drawing (Unit mm) 

Summary of Contents for SVD-H-105

Page 1: ...SVD 208 053 INSTRUCTION MANUAL AC VOLTAGE ALARM SETTER SVD 105 SVD 105D With contact delay circuit...

Page 2: ...product wet to prevent heat generation ignition product failure When this product gets wet stop using it Do not connect metal excepting wiring to terminal in order to prevent heat generation ignition...

Page 3: ...Performance 4 2 3 Control output condition 5 3 Handling explanation 3 1 Outline dimension 6 3 2 Installation 6 3 3 Connection 7 3 4 Handling explanation 7 3 4 1 Settings 7 3 4 2 Cautions on connectio...

Page 4: ...AC DC80 264V AC100 110V 50 60Hz AC200 220V 50 60Hz DC100 110V AC power 5 7VA DC power 2 2W DC38 58V DC48V 2 2W DC19 29V DC24V 2 2W Output Contact output Each 1c Contact capacity Maximum switching load...

Page 5: ...voltage Between electric circuit and case AC2000V 50 60Hz 1 minute Between input terminals and auxiliary supply terminals and contact output terminals Impulse withstand voltage Between electric circu...

Page 6: ...2 1 3 OFF L HL type Power and input conditions Drawing of input state Contact status LED indication status At contact operating ON L H Power OFF L 0 F S H 10 9 11 2 1 3 OFF OFF L H Power ON Input L L...

Page 7: ...ation dust and corrosive gas And please select indoors without the influence of the strong electric magnetic field by the large current bus saturable reactor Please prepare the installation interval m...

Page 8: ...tection action may be done even if it does not exceed set value They are not the abnormalities of a product 2 Variable of dead band It can do continuation variable of the dead band in dead band variab...

Page 9: ...an accident beforehand please check an operation value periodically Caution 1 Please do not make a wiring change of the input and auxiliary supply in an energization 2 Please check a connection diagr...