23
©
2014
Daikin
North
America,
LLC
Standard
Horizontal
Terminations
(Dual
Pipe)
Vent
Terminations
Also,
may
not
terminate
over
a
public
walkway,
or
over
any
area
where
condensate
or
vapor
could
cause
a
nuisance
or
hazard
.
The
combustion
air
intake
termination
of
a
direct
vent
application
should
not
terminate
in
an
area
which
is
frequently
dusty
or
dirt
.
12”
Min
to
Grade
or
Highest
Anticipated
Snow
Level
Vent
Flue
Pipe
(Tee
Optional)
Combustion
Air
Intake
(Optional)
10”
– 24”
©
2014
Daikin
North
America,
LLC
Side
Wall
Vent
Kit
Concentric
Vent
Terminations
(side
wall)
Used
with
2”
or
3”
direct
vent
systems
.
May
be
installed
with
the
intake
and
exhaust
pipes
located
side
‐
by
‐
side
or
with
one
pipe
above
the
other
.
Not
intended
for
use
with
single
pipe/
non
‐
direct
vent
installations
.