8 | Setup and installation
AHT Cooling Systems GmbH | en
44 / 84
417632_2_0820
CAUTION
Sharp edges of the appliance. Heavy
appliance parts.
Cutting injuries to the hands. Hands may be-
come trapped.
§
Take care of fingers and hands when un-
packing.
§
Wear protective gloves.
NOTICE
Material and property damage due to missing
parts in the appliance.
§
Check the packaging for loose parts.
§
Do not dispose of loose parts; clarify their use with
the maintenance service
[see
.
8
Setup and installation
Responsibility
– Qualified staff
WARNING
Damage to the refrigerant circuit.
Flammable refrigerant can escape and cause
an explosive gas/air mixture. Fire hazard.
§
Do not obstruct the ventilation openings in
the appliance housing. Use only original
accessory parts.
§
Only install the appliance in well-ventilated
rooms.
§
If the appliance is installed in cellars, you
must ensure that there is sufficient ventila-
tion.
§
Ducts and wall bushings must be sealed
under and behind the unit to protect
against fire.
§
Do not drill holes in the appliance and do
not carry out any other work on the appli-
ance.
§
Do not crush or bend pipes.
CAUTION
Material breakage.
Falling hazard. Impact hazard due to the pos-
sibility of falling goods. Cuts.
§
Do not climb onto or into the appliance.
Sharp edges of the appliance. Heavy
appliance parts.
Cutting injuries to the hands. Hands may be-
come trapped.
§
Take care of fingers and hands when un-
packing.
§
Wear protective gloves.
NOTICE
Material and property damage due to incor-
rect setup.
§
Operate the appliance in a stable operating posi-
tion (horizontal alignment).
§
Operate the appliance only on the designated ad-
justable feet.
§
Do not expose the appliance to direct heat radi-
ation at the place of installation, e.g.:
- Sunlight
- Artificial external light sources
§
Do not expose the appliance to direct air condition-
ing or ventilation at the place of installation.
§
Do not install the appliance outdoors.
Material and property damage caused by
damage to the doors.
§
Adhere to minimum clearance around the appli-
ance. Doors must be capable of being opened
without obstruction.
Material and property damage due to accumu-
lation of warm exhaust air (heat accumula-
tion).
§
The exhaust air must be able to escape freely at
the top of the appliance.
Minimum clearance from ceiling 1000 mm.
Lower minimum clearance by agreement with the
manufacturer only.
§
Superstructures or false ceilings directly on the up-
per edge of the appliance may only be installed in
consultation with the manufacturer.
§
To blow out the warm air, at least 300 mm must
remain free between the ceiling and any suspen-
ded marketing posters.
Lower minimum clearance by agreement with the
manufacturer only.
Only qualified staff may set up and install the appli-
ance or a group of appliances (assembly, sealing).
This work must be performed according to the
KALEA GM FR assembly instructions.
These instructions are available from qualified staff.
The installation of an appliance or group of appliances
and the external unit must be performed by qualified
staff in consultation with the operator.
The operator must provide the following infrastructure
in fully operational state before delivery and installa-
tion of the appliances and bears the responsibility for
these systems and interfaces to be connected:
– Power supply
– Wastewater drainage - defrosting water drain con-
nection
– Overall market control
– DFU access for remote maintenance (optional)
Technical data for interfaces
[see
.
Technical modifications to the appliance only in agree-
ment and after approval of the manufacturer.