13
Bef
ore
Operation
Handling
Specifications (AKJZ568/908)
2.0
3.0
5.0/5.6
8.0/9.0
AKZJ568
AKZJ908
4.0kVA/11.4A
4.0kVA/11.4A
4.8kVA/12.5A
Same as standard
Same as standard
Same as standard
3.3kVA/9.4A
3.3kVA/9.4A
3.4kVA/9.0A
7.5kVA/21.6A
7.5kVA/21.6A
9.0kVA/23.7A
3.9kVA/11.2A
4.1kVA/11.7A
4.3kVA/11.2A
Same as standard
Same as standard
Same as standard
Equivalent to 1.5 kW
Equivalent to 2.2 kW
–H
–E
∗
3
Standard
–B
–C
1450×470×500
1450×560×710
1630×560×620
1630×655×830
86
160
83
15 (Required for the models other than “–B”)
20 (Required for the models other than “–B”)
30
20
140
220
132
3-phase 200/200 · 220 VAC 50/60 Hz
∗
3
3-phase 200/200 · 220 VAC 50/60 Hz
3-phase 200/200 · 220 VAC 50/60 Hz
DC12/24V
White
Open coil type
Cross fin coil type
1
φ
, 50 W, 4P
Room temperature or machine temperature
∗
4
(Factory setting: Room temperature: Mode 3)
Tank liquid temperature
Within ±9.9 relative to reference temperature (Factory setting: 0.0)
Tank liquid temperature
5–50
Inverter compressor rotation speed + Electronic expansion valve opening
5–45
5–50
0.5–200
Water-soluble cutting/grinding fluid, Cutting/grinding oil, Lubricating oil, Hydraulic oil, Water for industrial use
(Note: Inapplicable to chemicals, foods and fuels)
Vertical: 14.7 m/s
2
(1.5 G) × 2.5 hr (10 to 100 Hz sweep/5 min)
Agitator inner thermostat, Reverse-phase protector, Restart prevention timer, Low room temperature protection thermostat, High oil temperature
protection thermostat, Low oil temperature protection thermostat, Discharge pipe temperature thermostat, Condenser temperature thermostat,
Refrigerant leak detector, Inverter protector, No-fuse breaker (“–B” only), High-pressure pressure switch (“–C” only), Compressor protection
thermostat (“–C” only), Overheat prevention temperature thermostat (“–H” only), Fuse (“–H” only)
∗
3
5kVA
6kVA
–H
–E
∗
3
Standard
–B
–C
2
4
φ
400, 90 W×4P
φ
450, 150 W×4P
1.25
1.65
65
68
Tank (Depth: 400 mm or more), supply pump, float switch, return filter
15
20
Oil Cooling Unit equivalent horsepower (HP)
Cooling capacity (50/60 Hz)
∗
1
kW
kW
200 V 50 Hz
200 V 60 Hz
220 V 60 Hz
mm
K
˚C
˚C
˚C
kg
Heater
Power supply
∗
2
Transformer capacity
Exterior color
Outer dimensions (H × W × D)
Compressor (Fully-enclosed DC swing type)
Evaporator
Condenser
Propeller fan
Motor
Refrigerant control
Local procurement
item
Circuit breaker (Rated current)
Other than circuit breaker
Refrigerant (New refrigerant: R410A)
∗
5
Loading weight
Applicable oil
Protection device
Temperature
control
Tuning
type
Fixed
type
Reference
Control target
Tuning range
Control target
Range
Motor
Agitator
Max. power consumption
Max. current consumption
Main circuit
Operation circuit
Circuit voltage
Model
(Selectable)
Operating range
Oil viscosity
Tank liquid temperature
Room temperature
Transportation vibration resistance
kg
Weight
A
Internal circuit breaker (Rated current)
A
Sound level (Measured at 1 m from front of unit,
at 1 m height, in anechoic room)
dB (A)
Note)
∗
1: Cooling capacity is the value at standard point (inlet oil temperature and room temperature: 35˚C, ISO VG32 oil). The product tolerance is
approx. ±5%.
∗
2: Be sure to use a commercial power supply. Using an inverter power supply may result in burnout. Voltage fluctuation range should be
within ±10%.
If voltage fluctuation exceeds ±10%, consult DAIKIN.
∗
3: For the different-voltage model, three types (–E1, –E2 and –E3) are available depending on the power supply voltage. (see page .)
∗
4: The optional machine temperature tuning thermistor is required. (For details, see page .)
∗
5: The “–C” model is supplied with MSDS (Material Safety Data Sheet) for refrigerant R410A.
∗
6: This product is not equipped with a circuit breaker. The user must prepare a circuit breaker.
∗
7: Conventional “1 HP”-equivalent models (AKJ106/AKZJ287 class) have been integrated into AKZJ358 (“1.2 HP”-equivalent).
34
12
PIM00132A_EN.fm 13 ページ 2007年9月20日 木曜日 午後3時4分