3 Operation

Operation manual

5

D2C18ND0 D2HND012/18A5AA
Wall-mounted condensing boiler
3P469438-9H – 2018.05

▪ Virtual room temperature (with outdoor sensor)

▪ Domestic hot water set temperature

▪ System pressure (at standby mode)

3.3.2

To select the operation mode

The operation mode can be changed by pressing the "Mode" button
(

).

(5 s)

(5 s)

a

c

b

d

e

a

Central heating only mode

b

Standby mode

c

Summer mode

d

Winter mode

e

Full-off mode

3.3.3

Possible operation modes

Operation mode

Description

Central heating only mode

▪ Only central heating operation mode

is enabled.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central heating operation modes" on
page  6

)  and  the 

  icon  is  shown

on the home screen.

▪ The    icon  blinks  if  central  heating

operation is active.

Standby mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ The  protection  functions  such  as

frost  protection  are  still  active  at
standby mode.

▪ The home screen shows the system

pressure, as well as the   icon.

Summer mode

▪ Only  domestic  hot  water  operation

mode  is  enabled.  Central  heating
operation  mode  is  disabled.  The
boiler  will  only  produce  heat  for
domestic hot water.

▪ The  domestic  hot  water  setpoint,

and  the 

  icon  is  shown  on  the

home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

Operation mode

Description

Winter mode

▪ Both  domestic  hot  water  operation

mode  and  central  heating  operation
mode  are  enabled.  The  boiler  can
produce domestic hot water, as well
as produce heat for central heating.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central heating operation modes" on
page  6

),  and  the 

  icon,  as  well

as  the 

  icon  are  shown  on  the

home  screen.  When  domestic  hot
water  operation  is  active,  domestic
hot  water  setpoint  is  shown  on  the
home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

▪ The    icon  blinks  if  central  heating

operation is active.

Full-off mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ LCD  display  will  be  darkened  and

will  not  be  activated  with  any  user
interaction.

▪ The  protection  functions  such  as

frost protection are still active at full-
off mode.

▪ Full-off  mode  is  activated  and

deactivated  if  "Mode"  button  is
pressed for 5 seconds while boiler is
in any mode.

3.3.4

Changing temperature setpoints

Temperature setpoints can be changed with the Right/Left dials.

To change the central heating temperature
setpoint

1

Turn the left dial while you are at the home screen. The setpoint
screen  will  appear  as  shown  below  and  the  setpoint  can  be
adjusted by turning the left dial. 

Note: 

The   icon means you are

at the setpoint screen.

2

To apply changes done, wait for 3 seconds or press the "Enter"
button. Pressing the "Cancel" button cancels the changes done.

Summary of Contents for Altherma 3 C Gas W D2HND-A5A

Page 1: ...eration manual Wall mounted condensing boiler English Manuel d utilisation Chaudi re murale condensation Fran ais Operation manual Wall mounted condensing boiler D2C18ND024A5AA D2HND012A5AA D2HND018A5...

Page 2: ...the unit See table below Model Type Domestic hot water supply D2C18ND024A5AA D2C18ND024 Instantaneous D2HND012A5AA D2HND012 Heating only D2HND018A5AA D2HND018 Heating only A control unit which contain...

Page 3: ...Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is...

Page 4: ...domestic hot water the ring flashes to its maximum then constantly keeps glowing during burner operation Error The status indicator will go into error mode when a warning lockout or blocking error occ...

Page 5: ...ter operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well a...

Page 6: ...ing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating operation mode i...

Page 7: ...ICE When not using the boiler we strongly recommend not to cut off the electric supply to the boiler 3 3 10 About Energy Metering Function This function provides user to read electricity and gas consu...

Page 8: ...ric energy consumption Domestic hot water Last month kWh Description short Unit F42 d Electric energy consumption Domestic hot water Current month kWh F43 d Electric energy consumption Domestic hot wa...

Page 9: ...For this parameter value to be active reducing mode has to be enabled by your service agent otherwise central heating mode will not be activated when there is no heat demand U07 When On Off room therm...

Page 10: ...lution 10 64 Gas valve circuit error Perform reset If problem repeats contact your service agent 10 65 Gas valve current error Perform reset If problem repeats contact your service agent 11 64 Ignitio...

Page 11: ...the system pressure to 0 8 bar HJ 10 Water pressure sensor fault Contact your service agent J6 01 Flow temperature sensor overheating Can be a blocking error or a lockout error Check the valves of the...

Page 12: ...fage central Le type d alimentation d eau chaude peut tre instantan ou par l interm diaire d un r servoir de stockage d eau chaude Les chaudi res uniquement chauffantes ne fournissent pas d eau chaude...

Page 13: ...ntenance ou une r paration vous m me Faites appel un agent d entretien qualifi ATTENTION N utilisez pas de sprays de solvants d agents de nettoyage chlor s de peinture et d adh sifs proximit de l unit...

Page 14: ...s param tres du menu L cran cristaux liquides dispose d une fonction de veille Au bout d une minute de non interaction avec l interface utilisateur l cran s assombrit Appuyer sur un des boutons ou tou...

Page 15: ...eau chaude sanitaire Il s agit du comportement habituel 3 3 Utilisation de base 3 3 1 propos de l cran d accueil Il s agit de l cran qui s affiche apr s l activation de l cran cristaux liquides l aid...

Page 16: ...consigne de la temp rature peuvent tre modifi s l aide des molettes gauche droite Modification du point de consigne de la temp rature du chauffage central 1 Tournez la molette gauche en tant l cran d...

Page 17: ...chauffage central est activ REMARQUE En cas de conception mauvaise ou inadapt e du circuit de chauffage central qui provoquerait un d gagement de chaleur inad quat dans l espace de s jour activer le m...

Page 18: ...le statut de l indicateur de statut est affect Cependant veuillez noter que toutes les erreurs n ont pas le m me effet sur l interface utilisateur et l indicateur de statut Type d erreur Fonctionnemen...

Page 19: ...mation d nergie lectrique eau chaude sanitaire mois actuel kWh F43 d Consommation d nergie lectrique eau chaude sanitaire ann e actuelle kWh a Ne s applique pas si le capteur n est pas raccord b Valeu...

Page 20: ...ture int rieure virtuelle s il n y a pas de demande de chauffage Note Pour que cette valeur de param tre soit active le mode de r duction doit tre activ par votre agent d entretien autrement le mode c...

Page 21: ...olets la nuit Ne cachez pas de radiateurs derri re de grands meubles c est dire un canap un bureau etc Il faut garder une distance d au moins 50 cm sinon l air chaud ne peut pas circuler et la pi ce n...

Page 22: ...circuler Votre chaudi re fonctionnera nouveau au bout d un moment Si le probl me se r p te contactez votre agent d entretien 8H 65 Diff rence de temp rature d part retour trop lev e Veillez ce que les...

Page 23: ...xion du thermostat d ambiance Opentherm est d fectueuse Votre chaudi re continuera fonctionner mais le thermostat d ambiance Opentherm est hors service Contactez votre agent d entretien U4 66 Expirati...

Page 24: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469438 9H 2018 05...

Reviews: