Set-up and installation
Installation and maintenance instructions
13
Daikin Altherma EHS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444099_01 – 11/2018 – EN
Fig. 4-4
Dimensions, top of the device - Type …04P50D/…
08P50D
Item
Designation
1
Solar - inflow
2
Cold water
3
Domestic hot water
4
Heating inflow
5
Heating return flow
6
Connection for refrigerant gas line
7
Connection for refrigerant fluid line
8
Biv – inflow (…Biv type only)
9
Biv – return flow (…Biv type only)
A
front
B
rear
Tab. 4-1
4.2
Transport and delivery
WARNING
When unfilled, the indoor unit is top-heavy and could tip
over during transport. That could put persons in danger or
damage the unit.
▪ Secure the indoor unit well, transport carefully, use the
handles.
The indoor unit is delivered on a pallet. All industrial trucks, such as
lifting trucks and forklift trucks, are suitable for transporting it.
Scope of delivery
▪ Indoor unit (pre-mounted),
▪ Bag of accessories (see
Fig. 4-5
),
▪ Document pack.
Fig. 4-5
Contents of bag of accessories
Item
Designation
Item
Designation
A
Handles (only required
for transport)
G
O-ring
B
cover panel
H
Cable tie
C
Hose connecting piece
for safety overflow
I
Plug bracket
D
Assembly wrench
J
Venting hose
E
Ball valve
K
Drain hose cover
F
Flat gasket
L
Controller rotary switch
Tab. 4-2
For further accessories for the indoor unit, see price list.
4.3
Installing the heat pump
4.3.1
Selecting the installation site
CAUTION
If the total refrigerant charge in the system is ≥ 1.84 kg, it is
essential to comply with additional requirements for min-
imum footprint and minimum ventilation openings.
Observe
Chap. 10.5
.
Information on the total refrigerant charge can be found on
the type plate of the outdoor unit. Please follow the installa-
tion instructions.
The installation site of the indoor unit must meet the minimum re-
quirements below (see also
Chap. 1.2.3
).