10
Technical data
Installation and maintenance instructions
58
Daikin Altherma EHS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444099_01 – 11/2018 – EN
Refrigerant circuit pipe connections
Number
—
2
Fluid line type
—
Flanged connection
Fluid line outer Ø
inches
1/4" male
Gas line type
—
Flanged connection
Gas line outer Ø
inches
5/8" male
Operating range
Inflow temperature for room heating, room cooling function -
heating (min/max)
°C
18 to 65
Inflow temperature for room heating, room cooling function -
cooling (min/max)
°C
5 to 22
Domestic hot water preparation (with EKBUxx) - Heating (min/
max)
°C
25 to 80
Noise level
Audibility
dBA
39.1
Voltage supply
Phases
—
1
Voltage
V
230
Voltage range
V
Voltage ±10%
Frequency
Hz
50
Mains connection
(4)
Heat pump outdoor unit
—
3G
Optional auxiliary heater (backup heater EKBUxx)
—
3G (1-phase) / 5G (3-phase)
10.2
Information on the type plate
Fig. 10-1
Type plate
Item
Designation
Item
Designation
1
Device type
13
Electrical power con-
sumption elmax
2
Empty weight
14
Backup-heater (optional)
3
Total filled weight
15
Backup heater protec-
tion class (optional)
4
Max. permissible operat-
ing pressure PMS (heat-
ing)
16
Backup heater fuse (op-
tional)
5
Total storage capacity
17
Output/backup heater
power supply (optional)
To select; 0 kW: no/ex-
ternal heat source
6
Max. permissible operat-
ing temperature T
max
18
Refrigerant circuit
Item
Designation
Item
Designation
7
Standby heat expendit-
ure in 24 hours at 60 °C
(storage tank Q
st
19
Max. operating pressure
(refrigerant circuit)
8
Operating pressure of
storage water pH
2
O
20
Total filling quantity of
refrigerant (for instruc-
tions, see installation in-
structions for heat pump
outdoor unit)
9
Nominal capacity of
drinking water
21
Attention: Flammable re-
frigerant
10
Max. operating pressure
PMW (plumbing)
22
For further information
on the refrigerant: see
instructions
11
Nominal voltage U
23
Serial number (specify in
the event of complaints
or inquiries)
12
Protection type
24
Date of production
(4)
Number of individual lines in the connection cable including protective earth conductor. The cross-section of the individual
lines is dependent on the current load, the length of the connection cable and the respective legal provisions.
Summary of Contents for Altherma 3 ECH2O