10
Technical data
Installation and maintenance instructions
63
Daikin Altherma EHS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444099_01 – 11/2018 – EN
Item
Designation
Item
Designation
Heat pump outdoor unit
K1
Relay 1 for backup heater
Heat pump indoor unit
K2
Relay 2 for backup heater
3UVB1
3-way switch valve (internal heat generator circuit)
K3
Relay 3 for backup heater
3UV DHW 3-way switch valve (hot water/heating)
X1
Terminal strip for backup heater mains connection
A1P
Printed circuit board (heat pump basic control)
X3
Plug connection for internal wiring to J17 (RoCon BM2C)
X26A
Plug connection to TRA1 (230 V)
FLS
Flow sensor
X31A
Plug connection to TRA1 (12 V)
HT/NT
Switching contact for low rate mains connection
X3A
Plug connection for internal wiring (bridging plug)
P
Heating circulation pump (connected inside the device)
X4A
Plug connection for FLS flow sensor and t
DHW2
P
Z
Circulation pump
X5A
Plug connection for t
V
inflow temperature sensor
PWM
Pump connection (PWM signal)
X6A
Plug connection for t
V, BH
inflow temperature sensor
RJ45 CAN Plug connection (RoCon BM2C) for internal wiring (for Ro-
Con+ B1)
X7A
Plug connection for temperature sensor (refrigerant fluid)
t
DC
RoCon+
B1
Controller control panel
X8A
Plug connection for return flow temperature sensor t
R
RoCon
BM2C
Printed circuit board (basic controller module)
X16A
Plug connection for heating circulation pump
X16A
Plug connection for heating circulation pump P
X18A
Plug connection to J11 of RoCon BM2C
J2
Plug connection for 3UVB1
X19A
Plug connection to XAG1 + J10 of RoCon BM2C
J3
Plug connection AUX switching contacts and cooling out-
put status output
X21A
Plug connection for internal wiring (bridging plug)
J5
Pressure sensor plug connection
AUX
Switching contact outputs (A-A1-A2) + (B-B1)
J6
Plug connection mains voltage
EKBUxx
Backup heater
J8
Plug connection for EXT
DS
Pressure sensor
Plug connection for EBA
EBA
Switching contact for external requirement request
Plug connection for Smart Grid EVU switching contacts
EXT
Switching contact for external operating mode changeover
Plug connection for outside temperature sensor t
V,BH
F1
Fuse 250 V T 2 A (RoCon BM2C)
Plug connection for storage tank temperature sensor t
DHW1
SG
Switching contact for Smart Grid (intelligent mains con-
nection)
Plug connection for HT/NT EVU switching contact
TRA1
Transformer
J10
Plug connection for internal wiring to X19A
t
A
Outside temperature sensor
J11
Plug connection for internal wiring to X18A (A1P)
t
DHW1
Storage tank temperature sensor 1 (RoCon BM2C)
J12
Plug connection for 3UV DHW
t
DHW2
Storage tank temperature sensor 2 (A1P)
J13
System bus plug connection (e.g. room station)
t
R
Return flow temperature sensor 2 (A1P)
J14
Circulation pump P
Z
plug connection
t
V1
Inflow temperature sensor 1 (A1P)
J15
Plug connection for internal wiring (bridging plug)
t
V, BH
Backup heater inflow temperature sensor
J16
Room thermostat (EKRTR / EKRTW) plug connection
EHS15706
8
Mixer module
HT/NT
Switching contact for low rate mains connection
EHS15703
4
Room station
XAG1
Heat pump outdoor unit plug connection
cooling
output
Status output for "Cooling" operating mode
(floor heating control connection cooling output)
XBUH1
Backup heater plug connection (EKBUxx)
RT
Room thermostat (EKRTW)
X2M6
HPc-VK-1 connection cable clamp
RT-E
Receiver for wireless room thermostat (EKRTR)
X2M7
HPc-VK-1 connection cable clamp
RTX-EHS Printed circuit board (backup heater)
X11M
Terminal strip in the HP convector
Tab. 10-26 Key names for connection and wiring diagrams