3 Unit installation
Installation manual
5
ETVH/9W(G)
Daikin Altherma 3 H HT F
4P586454-1 – 2019.07
5×
T25
2
Remove the user interface panel. Open the hinges at the top
and slide the top panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the user interface panel to prevent
damage.
2
1
1
3
3
Remove the switch box cover.
4×
T25
4
If necessary, remove the front plate. This is, for example,
necessary in the following cases:
▪
"3.2.2 To lower the switch box on the indoor unit"
▪
"3.3.2 To connect the drain hose to the drain"
▪ When you need access to the high voltage switch box
2×
T25
5
If you need access to the high voltage components, remove the
high voltage switch box cover.
4×
T25
3.2.2
To lower the switch box on the indoor unit
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite:
The user interface panel and front panel have been
removed.
1
Remove the fixing plate at the top of the unit.
2
Tilt the switch box to the front and lift it out of its hinges.
1
2
2×
T25