background image

4 Operation

Operation manual

5

EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V
+6V+9W
Daikin Altherma 3 R F+W
4P629084-2 – 2020.08

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

:  Turn,  then  press  the  left  dial.  Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

4.2

Possible screens: Overview

The most common screens are as follows:

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

4.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

26 Feb 2019

22:19

55

21
35

j

e2

l

k1
k2

k3

45

d

e1

g3

g2

h1

g1

f

i2 i3

i4

h2

i1

a2

a1

e3

b c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(a)

b Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

c Emergency

Heat pump failure and system operates in

Emergency

 mode or heat pump is forced off.

d Current date and time

e Smart energy

e1

Smart energy is available via solar panels or smart
grid.

e2

Smart energy is currently being used for space
heating.

e3

Smart energy is currently being used for domestic
hot water.

f

Space operation mode

Cooling

Heating

g Outdoor / quiet mode

g1

6

Measured outdoor temperature

(a)

g2

Quiet mode active

g3

Outdoor unit

h Indoor unit / domestic hot water tank

h1

Floor-standing indoor unit with integrated tank

Wall-mounted indoor unit

Wall-mounted indoor unit with separated tank

h2

Water pressure

Summary of Contents for Altherma 3 R F+W

Page 1: ...3 R F W EHBH04E 6V EHBH08E 6V EHBH08E 9W EHBX04E 6V EHBX08E 6V EHBX08E 9W EHVH04S U 18E 6V EHVH04S U 23E 6V EHVH08S U 18E 6V EHVH08S U 23E 6V EHVH08S18E 9W EHVH08S23E 9W EHVX04S18E 3V EHVX04S18E 6V EH...

Page 2: ...he documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Chec...

Page 3: ...battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste...

Page 4: ...a DHW tank is installed 3 1 Components in a typical system layout d a b c e f g B C A A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Garage a Outdoor unit...

Page 5: ...lues c3 Screen with weather dependent curve c4 Screen with schedule 4 2 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setp...

Page 6: ...g cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a ma...

Page 7: ...een Go through the list of settings Change the value Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can...

Page 8: ...options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month accord...

Page 9: ...tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tan...

Page 10: ...evel Browse through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed Advanced user pin code The Advanced user pin code is 1234 Addit...

Page 11: ...lid until the next programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the o...

Page 12: ...elect Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each charac...

Page 13: ...tivation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation...

Page 14: ...emperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature U...

Page 15: ...is displayed on the screen 7 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired roo...

Page 16: ...k if or is displayed on the home screen of the user interface See 7 1 To display the help text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P629084 2 2020 08 Copyright 2020 Daikin 4P629084 2 0000000S Verantwortung f r Energie und Umwelt...

Reviews: