background image

5 Operation

Operation manual

11

ELSH/X(B)12P30+50E
Daikin Altherma 3 R MT ECH

O

4P708485-1 – 2023.01

Item

Description

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

5.3.4

Detailed screen with values

Example: 

a

b

c

a

b

c

7.2.1

Time/date

Hours

11

30

Minutes

a

Settings

b

Values

c

Selected setting and value

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Confirm changes and proceed.

5.4

Turning operation ON or OFF

5.4.1

Visual indication

Certain  functionalities  of  the  unit  can  be  enabled  or  disabled
separately.  If  a  functionality  is  disabled,  the  corresponding
temperature icon in the home screen will be greyed out.

Space heating/cooling operation

55

21

35

45

a

55

21

35

45

b

a

Space heating/cooling operation ON

b

Space heating/cooling operation OFF

Tank heating operation

55

21

35

45

c

55

21

35

45

d

c

Tank heating operation ON

d

Tank heating operation OFF

5.4.2

To turn ON or OFF

Space heating/cooling operation

NOTICE

Room  frost  protection.

  Even  if  you  turn  OFF  space

heating/cooling  operation  ([C.2]: 

Operation

  > 

Space

heating/cooling

),  room  frost  protection  operation  –if

enabled–  can  still  activate.  However,  for  leaving  water
temperature  control  and  external  room  thermostat  control,
the protection is NOT guaranteed.

1

Go to [C.2]: 

Operation

 > 

Space heating/cooling

.

Operation

Space heating/cooling

Tank

Off

On

C.2

2

Set operation to 

On

 or 

Off

.

Tank heating operation

NOTICE

To  ensure  safe  operation  of  the  system,  do  NOT  turn  off
DHW when space heating is required.

NOTICE

Disinfection  mode

.  Even  if  you  turn  OFF  tank  heating

operation ([C.3]: 

Operation

 > 

Tank

), disinfection mode will

remain  active.  However,  if  you  turn  it  OFF  while
disinfection is running, an AH error occurs.

1

Go to [C.3]: 

Operation

 > 

Tank

.

Operation

Tank

Off

On

Space heating/cooling

C.3

2

Set operation to 

On

 or 

Off

.

5.5

Reading out information

To read out information

1

Go to [8]: 

Information

.

Possible read-out information

In menu…

You can read out…

[8.1] 

Energy data

Produced energy, consumed
electricity, and consumed gas,
energy flow diagram

[8.2] 

Malfunction history

Malfunction history

[8.3] 

Dealer information

Contact/helpdesk number

[8.4] 

Sensors

Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)

[8.5] 

Actuators

Status/mode of each actuator

Example: 

Domestic hot water

pump ON/OFF

[8.6] 

Operation modes

Current operation mode

Example: 

Defrost/oil return

mode

Summary of Contents for Altherma 3 RMT ECH2O

Page 1: ...n manual Daikin Altherma 3 R MT ECH O English Operation manual Daikin Altherma 3 R MT ECH O ELSH12P30E ELSH12P50E ELSHB12P30E ELSHB12P50E ELSX12P30E ELSX12P50E ELSXB12P30E ELSXB12P50E 1 2 3 9 A B C Z...

Page 2: ...be filled in by installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating th...

Page 3: ...nce Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT pla...

Page 4: ...ors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where yo...

Page 5: ...ernal room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the de...

Page 6: ...e temperatures Change the temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating coolin...

Page 7: ...e display Dials and buttons You use the dials and buttons To navigate through the screens menus and settings of the LCD screen To set values a b c d e Item Description a Left dial The LCD shows an arc...

Page 8: ...ar Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Mode Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comf...

Page 9: ...p failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is current...

Page 10: ...symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temperature zones Shows the appl...

Page 11: ...tection Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature con...

Page 12: ...to the Operation mode schedule 4 2 To restrict automatic changeover according to a schedule Conditions You set the space operation mode to Automatic 1 Go to 4 2 Space heating cooling Operation mode s...

Page 13: ...perature drops below a preset value set temperature hysteresis value example 40 C the tank is heated up to 50 C During the afternoon and evening you consume hot water again and the DHW tank temperatur...

Page 14: ...day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 2 Select Delete Delete Edit Copy 3 Select OK to confirm To program the schedule for Monday 1...

Page 15: ...operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor...

Page 16: ...temperature is heated increasingly more at decreasingly lower ambient temperatures Change the offset to equally increase or decrease the temperature of the leaving water for different ambient temperat...

Page 17: ...s how to fine tune the weather dependent curve of a zone or tank You feel Fine tune with slope and offset At regular outdoor temperatures At cold outdoor temperatures Slope Offset OK Cold You feel Fin...

Page 18: ...eater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that t...

Page 19: ...larly as in Manual mode the unit can take the full load with the backup heater or boiler if the user activates this via the Malfunctioning main menu screen When the heat pump fails or will appear on t...

Page 20: ...s 4 4 Solar 9 2 4 Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1 9 3 4 Additional capacity step 2 9 3 5 if applicable EN20190625 Emitter type 2 7 Control 2 9 Setpoint mode 2 4 Schedul...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P708485 1 2023 01 Copyright 2023 Daikin 4P708485 1 0000000U Verantwortung f r Energie und Umwelt...

Reviews: